Bunn Electric Brewing System LCR-2 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Machines à café Bunn Electric Brewing System LCR-2. Bunn Electric Brewing System LCR-2 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
! WARNING HOT LI
QUIDS
! AVERTISSEMENT LIQUIDES CHAUDS
POW
ER
READY
PO
R
TIO
N
RINSE
REFIL
L
ST
O
P!
HO
T
WATER
LCR-2
LCR-2A
LCR-2 PC
LCR-2A PC
INSTALLATION & OPERATING GUIDE
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts
Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at
www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and
manual updates. For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.
36026.0000T 06/11 ©2003 Bunn-O-Matic Corporation
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - LCR-2A PC

! WARNING HOT LIQUIDS! AVERTISSEMENT LIQUIDES CHAUDSPOWERREADYPORTIONRINSEREFILLSTOP!HOT WATERLCR-2LCR-2ALCR-2 PCLCR-2A PCINSTALLATION & OPE

Page 2 - 36026 050511

10OPERATING CONTROLS AND INTERFACE1a. Dispense Handles: Pull and Hold to dispense product.1b. Dispense Switches: Push and Release to dispense product

Page 3 - INTRODUCTION

11INITIAL FILL & HEAT1. Select Normal on the Function Selector Switch and Run on the Mode Selector Switch.2. Confirm the water supply is on.3. Co

Page 4 - USER NOTICES

12FlavorGard™ FeatureFlavorGard™ is a patented feed back control loop that monitors the mixed product and adjusts the concentrate delivery rate to mai

Page 5 - 39762.0000

13Rinse Procedure:1. Open the cabinet door and select Rinse on the Function Selector switch – close the door.2. Place a 2 Liter (1/2 Gal) container

Page 6 - CE REQUIREMENTS

14PROGRAMMING THE DISPENSERRemove the lower splash guard assembly to access the digital programming module with LCD display.Press the Down Arrow key t

Page 7 - LEVELING THE DISPENSER

15 MENU SCREEN ACTION DESCRIPTIONLOCK FLAVOR ? EXIT YESFLAVORS LOCKEDEXITSelect (YES) or (EXIT)NONESelect YES, to Lock I

Page 8 - SETTING DISPENSER FLOW RATE

16ENTER PASSWORD(-) 0 (+)The following functions can be Password Protected. If you wish to prevent others from accessing these functions, en

Page 9 - Lubricate New Tube

1736026 120105 MENU SCREEN ACTION DESCRIPTIONCAL LEFT PUMP ?PULL DISPENSECAL LF PUMP VOL(-) 43mL (+)CAL LF WTR FLOW ?PULL DISPENSERC

Page 10 - 36026 120105

1836026 120105 MENU SCREEN ACTION DESCRIPTIONCAL RIGHT PUMP ?PULL DISPENSERCAL RT PUMP VOL(-) 43mL (+)CAL RT WTR FLOWPULL DISPENSERC

Page 11 - INITIAL FILL & HEAT

19 MENU SCREEN ACTION DESCRIPTION36026 073107BIB EMPTY -> 500(-) EXIT (+)XX REFILL -> 155(-) EXIT (+)WTR START DELAY(-) .1

Page 12 - Rinse Alarm Feature

236026 050511BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTYBunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:1) All equipment oth

Page 13 - BIB Empty Lockout Feature

20LOADING THE CONCENTRATE1. Thoroughly mix concentrate by vigorously shaking the product Bag-In-Box (BIB).2. Pull the BIB connector through the hole

Page 14 - PROGRAMMING THE DISPENSER

21Filling Cambros or other large containers:The dispenser is designed primarily for cups or other small containers that will fit under the dispense tip

Page 15

22OPERATING THE PRESET PORTION CONTROL DISPENSER(Models LCR-2 PC, LCR-2C PC, LCR-2A PC)Set the Function Selector Switch to Normal and the Mode Select

Page 16

23CLEANING & PREVENTATIVE MAINTENANCEGeneral Cleaning and Sanitizing ProceduresNote: The BUNN® Liquid Coffee Dispenser incorporates a “user select

Page 17

24REPLACING THE PUMP TUBINGThe pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, the tubes are a

Page 18

25DRAINING THE HOT WATER TANKCAUTION: The dispenser must be disconnected from the power source throughout these steps. 1. Disconnect the dispenser fr

Page 19 - 36026 073107

26Activate the Dispenser within 5 sec. to dispense the pre-selected volume.Front Panel LED Display MessagesAlternate Portion Dispenser Volume #2 has b

Page 20 - PRIMING THE CONCENTRATE LINES

27Troubleshooting (Continued)Replace BIB, see Loading the ConcentrateCheck BIB Connector Fittings Check Tubing Installat

Page 21 - 36026 042104

28LF TARGET RPMTOO HIGH !!TUBE TOO SMALLCHECK DISP RATIORT TARGET RPMTOO HIGH !!TUBE TOO SMALLCHECK DISP RATIOLF TARGET RPMTOO LOW !!TUBE TOO LARGECHE

Page 22

29Screen Displayed Possible Cause Troubleshooting ProceduresTroubleshooting (Continued)36026 041204Service RequiredService RequiredService Require

Page 23 - 36026 070709

3INTRODUCTION The Liquid Coffee Refrigerated Dispenser delivers two types of coffee made from liquid concentrate plus hot water. The dispenser can be

Page 24 - PREVENTIVE MAINTENANCE

30EVAP TEMP SENSOR OUT OF RANGECHECK WIRE FORSHORTSCOOLER FAULT!EVAP TEMP TOO HICHECK EVAP FANCHK EVAP SENSORCOOLING TIMETOO LONGCHECK AIR FILTERCHECK

Page 25 - DRAINING THE HOT WATER TANK

31Field Calibration of the Concentrate Pumps / Dispenser Flow RatesThe factory set Default Values for the Pump & Dispenser Flow Rates are very acc

Page 26 - Troubleshooting

32Dispenser Flow Rate Calibration13. Press Down Arrow Key to display the CAL LF WTR FLO menu screen.14. Place a 64 Oz (2000 ml) graduated container un

Page 27 - Troubleshooting (Continued)

33Field Calibrating the Empty BIB WarningThe dispenser will automatically turn on the Left or Right “REFILL LED”, see Operating Controls and Interface

Page 28

3436026 06221036025.0004A 07/10 © 2010 BUNN-O-MATIC CORPORATION120 VOLTS AC 2 WIRE120/208-240 VOLTS AC 3 WIRE208-240 VOLTS AC 2 WIRESINGLE PHASE 5

Page 29

3536026 06061136025.0001H 06/11 © 2003 BUNN-O-MATIC CORPORATION230 VOLTS AC2 WIRESINGLE PHASE50HZJ14-1J14-7J7-1J7-5J7-10J18-1J18-6J18-7J2-1J2 -8J3

Page 30

3636026 073107

Page 31

4USER NOTICESCarefully read and follow all notices on the equipment and in this manual. They were written for your protec-tion. All notices are to be

Page 32 - (Continued)

5ELECTRICAL REQUIREMENTSCAUTION: The dispenser must remain disconnected from power source until specified in Electrical Hook-Up. The LCR-2 dispenser

Page 33

6L1L2L3NL1FOR 3-PHASE OPERATIONCONNECT INPUT WIRING TOL1,L2,L3 & N AS SHOWN.FOR 1-PHASE/15 AMP. OPERATIONCONNECT INPUT WIRING TOL1 & N AS SHOW

Page 34 - SCHEMATIC WIRING DIAGRAM

7INITIAL SET-UPNOTE: The LCR-2 dispenser weighs approximately 100 lbs. (45 kg). If necessary, use more than one person when lifting or moving the di

Page 35 - SINGLE PHASE

8SETTING DISPENSER FLOW RATEThe dispenser comes from the factory with flow restrictors in the mix chambers. With the restrictors in place the dispense

Page 36

9SELECTING THE CORRECT PUMP TUBINGThere are two pump tube sizes available for use with this dispenser. To determine the correct tubing for your applic

Commentaires sur ces manuels