S6163-AK-FSE-0100910-LP-110-4363 REVISION 2TECHNICAL MANUALFORCOFFEE BREWER, BUNN-O-MATIC,MODELS C, CS, CRT, CRTF, CT, CTF, CW, CWTF,SINGLE CW AN
TITLE-2 Change A@@FIpgtype@@BLANK@@!FIpgtype@@
8C/CT/CWTF SeriesHOOD ASSEMBLIES8 23 24 5 1 667P3910.540566 101507Part III
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE9HOOD ASSEMBLIES* Indicates the part number listed
10C/CT/CWTF SeriesAll models with receptacle and/or fuse (MV) are no longer availableTWIN-APSStandard & TCAPSEarly APS8222420156711214101113921116
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE11With Side Mounted Rocker Type Master ON/OFF Switc
12C/CT/CWTF Series40566 111308All models with receptacle and/or fuse (MV) are no longer availableTWIN-APSStandard & TCAPSEarly APS8222420156711214
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE13(1st type) separate Strainer & Flow ControlAl
14C/CT/CWTF Series40566 111308All models with receptacle and/or fuse (MV) are no longer availableTWIN-APSStandard & TCAPSEarly APS8222420156711214
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE1540566 111308* Indicates the part number listed is
16C/CT/CWTF Series40566 101507BASESTWIN-APS/TCAPS/TC/TSTWIN-2/2 & 4/2TWIN-0/61251312145101161512789517316615202122232519 18
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE17Continued on next page40566 101507* Indicates the
C, CT, CWTF SeriesIncluding DV, APS/TC/TS, Single CW & TwinsSupercedes Operating Manuals: 10690.####; 10737.####; 10841.0000;28182.0000; 36102.000
18C/CT/CWTF SeriesBASES40566 101507P3912.25TWIN-APS/TCAPS/TC/TSTWIN-2/2 & 4/2TWIN-0/61251312145101161512789517316615202122232519 18
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE19BASES40566 101507* Indicates the part number list
20C/CT/CWTF SeriesTANK AND COMPONENTSMulti-VoltDual-Volt1320W1800W3500W11341476135128 11 9 101522 21 1023 441320W1800W161712192018P3913.540566 101507P
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE21* Indicates the part number listed is for referen
22C/CT/CWTF SeriesMulti-VoltDual-Volt1320W1800W3500W11341476135128 11 9 101522 21 1023 441320W1800W161712192018TANK AND COMPONENTSP3913.540566 101507P
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE23* Indicates the part number listed is for referen
24C/CT/CWTF SeriesFILL BASIN AND LINES8 97First Style13 12 111086515215241314 57 13 9Second Style FittingP391440566 101507Part III
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE25* Indicates the part number listed is for referen
26C/CT/CWTF SeriesMANIFOLD AND LINES - LATER TWINS5 6 78 P4036.50421397 6 540566 040109Part III
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE27* Indicates the part number listed is for referen
Page 241721 100908BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTYBunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:1) All equipmen
28C/CT/CWTF SeriesEARLY MODELSSTRAINER/FLOW CONTROL AND LINES - EARLY TWINS9 10 1112 9 10 115 6 72 3 421 22208 1 13191411 10 9
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE29* Indicates the part number listed is for referen
30C/CT/CWTF SeriesMANIFOLD ASSEMBLIES - LATER SINGLESW/O Faucet (Optional)P40375123479681040566 040109Part III
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE31* Indicates the part number listed is for referen
32C/CT/CWTF SeriesSTRAINER/FLOW CONTROL - SECOND STYLE SINGLESW/O FaucetP391640566 0815082345671281181919 10 1114131715161Part III
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE33* Indicates the part number listed is for referen
34C/CT/CWTF SeriesSTRAINER/FLOW CONTROL - FIRST STYLE SINGLES234567Internal Strainer/Flow Control221623SECOND TYPE W/FAUCETFIRST TYPE W/FAUCET FIRST T
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE35* Indicates the part number listed is for referen
36C/CT/CWTF SeriesFILL SOLENOIDS151416111213967842321SKINNERKIPASCO105P391820181917ELTEK212240566 040109Part III
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE37* Indicates the part number listed is for referen
Page 341721 111308USER NOTICES ...
38C/CT/CWTF SeriesFAUCET AND TUBINGEarly Models41411 10 9 8 671213114235P391940566 101507Part III
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE39* Indicates the part number listed is for referen
40C/CT/CWTF SeriesWARMER ASSEMBLIES3145632456 7 UPPER & SIDE HOUSING WARMERS BASE WARMERS 7‘A” &”B” MODELS ONLY‘A” &”B” MODELS ONL
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE41* Indicates the part number listed is for referen
42C/CT/CWTF Series3233 Electronic ThermostatBrewers w/Fresh TimerBrewers w/Ready LightBrewers w/Switch Cover2028242319161423715133129383940202825202
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE43* Indicates the part number listed is for referen
44C/CT/CWTF SeriesELECTRICAL AND OPERATING CONTROLS3233 Electronic ThermostatBrewers w/Fresh TimerBrewers w/Ready LightBrewers w/Switch Cover2028242
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE45* Indicates the part number listed is for referen
46C/CT/CWTF SeriesELECTRICAL AND OPERATING CONTROLS3233 Electronic ThermostatBrewers w/Fresh TimerBrewers w/Ready LightBrewers w/Switch Cover2028242
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE47* Indicates the part number listed is for referen
Page 4USER NOTICESCarefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condi
48C/CT/CWTF SeriesELECTRICAL AND OPERATING CONTROLS3233 Electronic ThermostatBrewers w/Fresh TimerBrewers w/Ready LightBrewers w/Switch Cover2028242
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE49* Indicates the part number listed is for referen
50C/CT/CWTF Series40566 1113083233 Electronic ThermostatBrewers w/Fresh TimerBrewers w/Ready LightBrewers w/Switch Cover2028242319161423715133129383
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE5140566 111308* Indicates the part number listed is
52C/CT/CWTF SeriesFUNNELSBDACSST Gourmet ‘C’ FunnelSST ‘C’ FunnelPlastic ‘C’ FunnelPouch Pack Funnel531546 16142114151110141312159141516138P370340566
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE53* Indicates the part number listed is for referen
NUMERICAL INDEXPART NO. PAGE NO. PART NO. PAGE NO. PART NO. PAGE NO. PART NO. PAGE NO. 00310.0000... 31,33,3500310.0002...
12984.0004... 4512985.0000... 4712985.0003... 4713042.0001...
NUMERICAL INDEXPART NO. PAGE NO. PART NO. PAGE NO. PART NO. PAGE NO. PART NO. PAGE NO. 26285.0000... 1126285.0001...
Ref: NAVSEAINST 4160.3A NAVSEA S0005-AA-GYD-030/TMMP NAVSEA/SPAWAR TECHNICAL MANUAL DEFICIENCY/EVALUATION REPORT (TMDER) INSTRUCTIONS: Continue on 8
Page 5ELECTRICAL HOOK-UPCAUTION – Improper electrical installation will damage electronic components.1. An electrician must provide electrical servic
FOLD HERE AND TAPE SECURELY PLEASE DO NOT STAPLE INCLUDE COMPLETE ADDRESS USE PROPER POSTAGE FOR OFFICIAL USE ONLY COMMANDER
Ref: NAVSEAINST 4160.3A NAVSEA S0005-AA-GYD-030/TMMP NAVSEA/SPAWAR TECHNICAL MANUAL DEFICIENCY/EVALUATION REPORT (TMDER) INSTRUCTIONS: Continue on 8
FOLD HERE AND TAPE SECURELY PLEASE DO NOT STAPLE INCLUDE COMPLETE ADDRESS USE PROPER POSTAGE FOR OFFICIAL USE ONLY COMMANDER
S6163-AK-FSE-010
Page 6PLUMBING REQUIREMENTS-CURRENT SINGLESThis equipment must be installed to comply with the International Plumbing Code of the International Code C
Page 71. Remove six screws securing rear utility cover (if equipped). FIG 7-12. Remove cap from the flared fitting on the bottom of the center tube as
Page 8PLUMBING REQUIREMENTS-EARLY SINGLESThis equipment must be installed to comply with the International Plumbing Code of the International Code Cou
Page 9P1241TWINSTWINSThese brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620 kPa) from a 1⁄2
Page 10INITIAL SET-UPCAUTION - The brewer must be disconnected from the power source throughout the initial set-up, except when specified in the instru
Page 11ADJUSTING BREW VOLUMESCAUTION - Disconnect the power source from the brewer prior to the removal of any panel for the replacement or adjustment
Page 12ON/LOWER SWITCHPlacing the "ON/LOWER" switch in the "OFF" (lower) position stops brewing. Stopping a brew cycle after it h
Page 13MASTER ON/OFF SWITCH(S)The master ON/OFF switch disables power the entire brewer (including tank heaters). NOTE – TWINS with 2 power cords wil
Page 14COFFEE BREWING1. Insert a BUNN® filter into the funnel.2. Pour the fresh coffee into the filter and level the bed of grounds by gently shaking.
Page 15Clean Sprayhead HolesFIG 15-31. The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all sur
Page 16TROUBLESHOOTINGA troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the p
Page 17TROUBLESHOOTING (cont.)PROBLEMSpitting or excessive steaming Dripping from sprayheadBrew cycle starts when ON/LOWER Switch is turned on.Weak be
TITLE-2 Change A@@FIpgtype@@BLANK@@!FIpgtype@@
PART II Service and Repair Manual
S6163-AK-FSE-010 0910-LP-110-4363 REVISION 2 TECHNICAL MANUAL FOR COFFEE BREWER, BUNN-O-MATIC, MODELS C, CS, CRT, CRTF, CT, CTF
TITLE-2 Change A@@FIpgtype@@BLANK@@!FIpgtype@@
SERVICE & REPAIR MANUALBUNN-O-MATIC CORPORATIONPOST OFFICE BOX 3227SPRINGFIELD, ILLINOIS 62708-3227PHONE: (217) 529-6601 FAX: (217) 529-6644417
Page 241711.1 110909BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTYBunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:1) All equipm
Page 341711.1 052009 ContentsTrouble Shooting ...
Page 4TROUBLESHOOTINGA troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the pro
Page 5TROUBLESHOOTING (cont.)Brew cycle will not start (cont.) Water is not hotPROBABLE CAUSEREMEDY3. ON/OFF Switch4. Start Switch5. Timer6. Solenoid
Page 6TROUBLESHOOTING (cont.)Inconsistent beverage level in dispenserConsistently low beverage level in the dispenser Spitting or excessive steaming1.
Page 7TROUBLESHOOTING (cont.)Spitting or excessive steaming (cont.)Dripping from sprayheadWater fl ows into tank continu-ously (ON/OFF Switch "ON&
Page 8TROUBLESHOOTING (cont.)Weak beverageDry coffee grounds remain in the funnelBrewer is making unusal noises 1. Filter Type2. Coffee Grind3. Sprayh
Page 9TROUBLESHOOTING (cont.)Brewer is making unusal noises (cont.)Low beverage serving tempera-ture4. Tank Heater1. Warmer2. ON/OFF Switch Remove an
TITLE-2 Change A@@FIpgtype@@BLANK@@!FIpgtype@@
Page 10SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessar
Page 11SERVICE (cont.)OPTIONAL ELECTRONIC THERMOSTAT (ERT):The ERT is located inside the trunk on the upper left side of the component bracket.Test Pr
Page 12Location: The ON/OFF switch(s) are located on the front of the hood.Test Procedure:1. Disconnect the brewer from the power source.2. Viewing
Page 13SERVICE (cont.)START SWITCHESLocation: CRT/CRTF On brewers w/out fresh light, the start switch is located in the right front of the hood. On
Page 14SERVICE (cont.)SOLENOID VALVESLocation: The solenoid valve is located inside the trunk on the lower center part of the component bracket.Test
Page 1541711.1 052009120VAC - 1.18K 240VAC - 3.76K 120VAC - 247 240VAC - 757 120VAC - 334 SERVICE (cont.)SOLENOID VALVESDisassembly:1. Use of the bas
Page 16SERVICE (cont.)TANK HEATERLocation: The tank heater is located inside the tank and secured to the tank lid.Test Procedures:1. Disconnect the
Page 171800W-120V 7.40 - 8.70 1850W-220V 24.40 -28.40 3500W-200V 10.70 -12.36 3500W-240V 15.36 -17.90
Page 18SERVICE (cont.)TANK HEATER SWITCHLocation: The tank heater switch is located on the rear of the brewer on the upper left side of the trunk.Tes
Page 19SERVICE (cont.)TANK HEATER SWITCH (cont.)FIG. 19-1 TANK HEATER SWITCH TERMINALS15. Set tank assembly inside the hood on mounting brackets and
S6163-AK-FSE-010, Rev 2 31 Aug 2010 IDENTIFYING TECHNICAL PUBLICATION SHEET FOR COMMERCIAL MANUAL This manual supersedes S6163-AK-FSE-010, Rev 1, da
Page 20Location: The thermal cut-off (TCO) is a thermal fuse located above the tank lid, connected to the tank heater.NOTE: Installed only on tanks w
Page 21SERVICE (cont.)41711.1 052009COIL/FAUCETLocation: The coil for the faucet is located in the tank. Operation:Water inside the coil is separate
Page 22SERVICE (cont.)41711.1 052009LIMIT THERMOSTATLocation: The limit thermostat is located inside the rear ofthe hood on the tank lid.Test Procedu
Page 23RECOVERY BOOSTER RELAY (OPTIONAL)FIG. 23-1 RECOVERY BOOSTER RELAYLocation The recovery booster(s) are located inside the trunk on the center o
Page 24SERVICE (cont.)TIMER (Early Models) Location: The timer is located inside the front of the trunk on the upper right side of component bracket.
Page 25SERVICE (cont.)FRESHNESS TIMER (Early Models)Location: The freshness timer is located inside the front of the trunk on the component bracket.O
Page 26DIGITAL BREW TIMER (Late Models) FIG. 26-1 DIGITAL BREW TIMERSERVICE (cont.)Location: The timer is located inside the front of the trunk on th
Page 27Timer Setting:NOTE: Prior to setting or modifying volumes, check that the brewer is connected to water supply, the tank is properly fi lled, and
Page 28WARMER ELEMENT(S)Location: The warmer element(s) is located under the warmer plate.Test Procedures:1. Disconnect the brewer from the power s
Page 29L1BLKWHIBLKBLKBLKBLKBLK VIOBRN/BLKYELWHI/VIOLEFT FRONTWARMERLEFT REARWARMERRIGHT FRONTWARMERRIGHT REARWARMERBLK BLKTANK HEATERWHI (MODEL 20)NL2
TITLE-2 Change A@@FIpgtype@@BLANK@@!FIpgtype@@
Page 30L1BLKBLKBLKBLKBLKBLKBRN/BLKYELVIOWHI/VIOWHI/REDWHI/REDWHI/REDWHI/BLUREDREDREDREDREDREDREDWHI/GRNBREWTIMERT1 T5 T3T4T2BLUSTART SWITCHWHIBLK BLKG
Page 31L1BLKBLK WHI/REDWHI/REDWHI/REDBLKYELWHI/VIOBRN/BLKVIOBLKBLKBLKLOWER CENTER WARMERON/OFF SWITCHON/OFF SWITCHON/OFF SWITCHON/OFF SWITCHON/OFF SWI
Page 3210693.0000G 02/07 © 1993 BUNN-O-MATIC CORPORATION120/240 VOLTS AC 3 WIRE 120 VOLTS AC 2 WIRE SINGLE PHASE BREWTIMERWHIWHIWHIWHI/BLUWHI/GRN
Page 33 AUXILIARY OUTLET (200 WATT MAXIMUM)BLKE.R.TASSY.120/240 VOLTS AC 3 WIRE120 VOLTS AC 2 WIRESINGLE PHASEP1, P2, & P3 ARE PINS OF APOLARIZE
Page 34SCHEMATIC WIRING DIAGRAM FOR CWT-APS MV, CWTF-APS MV, CWTF-TS MV, CWTF-TSR MV41711.1 052009Part II
Page 3541711.1 052009Part II
Page 3641711.1 052009Part II
Page 3741711.1 052009Part II
Page 38BLK41711.1 052009Part II
Page 3941711.1 052009Part II
TABLE OF CONTENTS PART TITLE I Installation and Operating Guide II Service and Repair Manual III Illustrated Parts Catalog
Page 40WHI/RED LEFT LOWER WARMERWHI/REDWHI/GRNP1-2P1-3P4-2P4-3SCHEMATIC WIRING DIAGRAMCWT/CWTF TWIN 0/2, 2/2, 4/2 & CWT TWIN-APS(FAUCET)THERMALSA
Page 41WHI/RED LEFT LOWER WARMERWHI/REDWHI/GRNP1-2P1-3P4-2P4-3SCHEMATIC WIRING DIAGRAMCWT/CWTF TWIN 0/2, 2/2, 4/2 & CWT TWIN-APS(FAUCET)THERMALSA
Page 42WHI/REDWHI/GRNP1-2P1-3P4-2P4-3SCHEMATIC WIRING DIAGRAM CWTFA TWIN 2/2 & 4/2L1GRN/YELL2 L3RIGHT TANK HEATERBLK BLURT. READY INDICATORRT. SW.
Page 43BLK WHI/REDWHI/GRNP1-2P1-3P4-2P4-3SCHEMATIC WIRING DIAGRAMCWTFA & CWTFB TWIN 2/2 & 4/2L1GRN/YELL2(FAUCET)THERMAL FUSEBLKRIGHT TAN
Page 44BLK WHI/REDWHI/GRNP1-2P1-3P4-2P4-3SCHEMATIC WIRING DIAGRAMCWTFA 2/2 TWIN, CWTFA 4/2 TWIN & CWTFA TWIN-APS L1 L210736.0004A 02/06 © 2006
Page 45SCHEMATIC WIRING DIAGRAMCWTFA TWIN-APS CEL1GRN/YELL2BLK10736.0005B 08/07 © 2007 BUNN-O-MATIC CORPORATION230 VOLTS AC 2 WIRE + GNDSINGLE
Page 46GRYPINL.E.D.L.E.D.GRYPINGRYPINOPTIONALINDICATORTIMERWHI/REDWHI/GRNP1-2P1-3SCHEMATIC WIRING DIAGRAM CWTF TWIN 0/6(FAUCET)BLKBLKRIGHT TANK HEATER
Page 47WHI/BLUP3BLKP1, P2, & P3 ARE PINS OF A POLARIZED THREE-PIN CONNECTOR.BLUBLU/BLKWHIBREWTIMERP1P2WHIOPTIONAL AUTOMATIC BREW CIRCUITSCHEMATIC
Page 48P3P1, P2, & P3 ARE PINS OF A POLARIZED THREE-PIN CONNECTOR.BLUP1REDOPTIONAL AUTOMATIC BREW CIRCUITSCHEMATIC WIRING DIAGRAM CWTB10836.0002E
Page 49P3P1, P2, & P3 ARE PINS OF A POLARIZED THREE-PIN CONNECTOR.BLUP1REDOPTIONAL AUTOMATIC BREW CIRCUITSCHEMATIC WIRING DIAGRAM CWTA10836.0003E
TITLE-2 Change A@@FIpgtype@@BLANK@@!FIpgtype@@
Page 50P1, P2, & P3 ARE PINS OF A POLARIZED THREE-PIN CONNECTOR.SOLBREWTIMERREDRED10836.0004H 10/02 ©1997 BUNN-O-MATIC CORPORATION P2P1
Page 5120AMPT1T5 T3 T4T241711.1 052009Part II
Page 52P3BLKP1, P2, & P3 ARE PINS OF A POLARIZED THREE-PIN CONNECTOR.WHIBLKSOLBLU BLUWHIBREWTIMERP1P2WHIOPTIONAL AUTOMATIC BREW CIRCUITSCHEMATIC W
Page 53READY INDICATORBLKBLUSW. & THERMOSTATP3BLKP1, P2, & P3 ARE PINS OF A POLARIZED THREE-PIN CONNECTOR.WHIBLKSOLBLU BLUWHIBREWTIMERP1P2WHIO
Page 54T1T5 T3 T4T2BLK-14 BLK-14120V AC 2 WIRE120/208V AC 3 WIRE120/240V AC 3 WIRESINGLE PHASEWHI-14WHIWHIWHIWHI/REDWHI/REDWHI/REDWHIWHIWHIWHIWHIWHIW
Page 55T1T5 T3 T4T2BLK-14 BLK-14120V AC 2 WIRE120/208V AC 3 WIRE120/240V AC 3 WIRESINGLE PHASEWHI-14WHIWHIWHI/REDWHI/REDWHIWHI/GRNWHI/BLUWHI/VIO-14BL
Page 56BLUWHIBREWTIMERSCHEMATIC WIRING DIAGRAMSINGLE CW10836.0011B 01/03 ©2003 BUNN-O-MATIC CORPORATIONWHIWHIWHIWHIBLKWHI/REDLOWER WARMERSTART S
Page 57BLKWHIREDBLUTANK HEATERBLKLIMITTHERMOSTATLIMITTHERMOSTATSW1-LSW1-R(FAUCET SIDE)"KEEP WARM" HEATERSCHEMATIC WIRING DIAGRAMCWTF TWIN 4/
Page 58P4-2P4-3SCHEMATIC WIRING DIAGRAM CWT TWIN 2/2 & 4/2 W/RECOVERY BOOSTERREDWHIWHIWHILEFT TOP WARMERRIGHT TOP WARMERWHIP4-1YEL YELWHI/YEL WHI/
Page 59WHI/REDWHI/GRNP1-2P1-3SCHEMATIC WIRING DIAGRAM CWTF TWIN 0/6 WITH RECOVERY BOOSTERL1GREEN(FAUCET)THERMALSAFETY FUSEBLKBLKRIGHT TANK HEATERBLKBL
PART I Installation and Operating Guide
TITLE-2 Change A@@FIpgtype@@BLANK@@!FIpgtype@@
PART III Illustrated Parts Catalog
TITLE-2 Change A@@FIpgtype@@BLANK@@!FIpgtype@@
ILLUSTRATED PARTS CATALOGDesigns, materials, weights, specifications, and dimensions for equipment or replacement partsare subject to change without no
40566 110909BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTYBunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:1) All equipment othe
340566 111308TOP COVERS ...
4C/CT/CWTF SeriesTOP COVER ASSEMBLIES-SINGLES9 11All models with brass covers/panels are no longer available40566 021109181712211674182010135614191523
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE5TOP COVER ASSEMBLIES-SINGLES 1 02999.0000 - 1
6C/CT/CWTF SeriesTOP COVER ASSEMBLIES-TWINS40566 101507APS/TC & 0/6All covers/housings include flip lids &/or decals as required.4/2145239672/2
ITEM PART NO. QTY. QTY. DESCRIPTION TWIN SINGLE7TOP COVER ASSEMBLIES-TWINS* Indicates the part num
Commentaires sur ces manuels