Timer Setting:
NOTE: Prior to setting or modifying volumes, check
that the brewer is connected to water supply, the
tank is properly filled, and a funnel and server are in
place.
NOTE: All volume settings must be done with the
sprayhead installed.
1. Modifying brew volumes. To modify a brew vol-
ume,rstcheckthattheSET/LOCKswitchisinthe
“SET” position on the circuit board.
To increase a brew volume, place the ON/OFF
switch in the “ON” position, press and hold the START
switch until three clicks are heard. Release the switch
and press it again one or more times. (Failure to re-
lease the switch within two seconds after the third click
causes the volume setting to be aborted and previous
volume setting will remain in memory) Each time the
switch is pressed, two seconds are added to the brew
time period. Allow the brew cycle to finish in order to
verify that the desired volume has been achieved.
To decrease a brew volume, place the ON/OFF
switch in the “ON” position, press and release the
START switch once for every two-second interval to
be removed from the total brew time period; then im-
mediately press and hold down the START switch until
three clicks are heard. Release the switch. (Failure to
release the switch within two seconds after the third
click causes the volume setting to be aborted and
previous volume setting will remain in memory). Al-
low the brew cycle to finish in order to verify that the
desired volume has been achieved.
2. Setting brew volumes. To set a brew volume,
rstcheckthattheSET/LOCKswitchisinthe“SET”
position on the circuit board. Place the ON/OFF switch
in the “ON” position, press and hold the START switch
until three distinct clicks are heard and then release
the switch. (Failure to release the switch within two
seconds after the third click causes the volume setting
to be aborted and previous volume setting will remain
in memory.
View the level of the liquid being dispensed. When
the desired level is reached, turn the ON/OFF switch
to “OFF”.
NOTE: Several ounces of water will continue to sy-
phon from the tank after turning the switch “OFF”.
The brewer remembers this volume and will continue
to brew batches of this size until the volume setting
procedure is repeated.
NOTE: When brewing coffee, volume will decrease
due to absorption by the coffee grounds.
3. Setting programming disable feature. If it be-
comes necessary to prevent anyone from changing
brew time once programmed, you can set the SET/
LOCKswitchtothe“LOCK”position.Thiswillprevent
any further programming until switch is once again
put into the “SET” position.
BLU wire to TL5 from start switch
WHI/GRN wire to TL4 from solenoid
WHI/BLU wire to TL3 from solenoid
WHI wire to TL2 from N/L2
WHI/RED wire to TL1 from on/off switch
FIG. 27-1 DIGITAL TIMER WIRING
SERVICE (cont.)
DIGITAL BREW TIMER (Late Models)(cont.)
41711.1 052009