Bunn FMD-2 Manuel de service Page 25

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 24
25
SERVICE (cont.)
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the
wiring diagram and check the dispenser wiring haness.
5. Reconnect the violet wire to terminal 1.
6. Carefully connect a piece of insulated jumper wire
to terminal 4. Keep the other end of this wire away
from any metal surface of the dispenser.
7. Check the voltage across terminals 1 & 3 with a
voltmeter. Connect the dispenser to the power
source. The indication must be 120 volts ac for two
wire 120 volt models, three wire 120/208 volt
models, three wire 120/240 volt models and 240
volts ac for two wire 240 volt models after a delay
of approximately 5 seconds.
8. Touch the free end of jumper wire to the dispenser
housing. The indication must be 0.
9. Move the jumper wire away from the dispenser
housing. The indication must again be 120 volts ac
for two wire 120 volt models, three wire 120/208
volt models , three wire 120/240 volt models and
240 volts ac for two wire 240 volt models after a
delay of approximately 5 seconds.
10. Disconnect the dispenser from the power source
and remove the jumper wire from terminal 4.
If voltage is present as described, the level control
board is operating properly, proceed to #11.
If voltage is not present as described, replace the level
control board.
11. Reconnect the pink wire to terminal 4.
12. Gently pull the probe out of the tank lid and inspect
for corrosion. Replace it if necessary.
13. Place the probe so that neither end is in contact
with any metal surface of the dispenser.
14. Check the voltage across terminals 1 & 3 with a
voltmeter. Connect the dispenser to the power
source. The indication must be 120 volts ac for two
wire 120 volt models, three wire 120/208 volt
models, three wire 120/240 volt models and 240
volts ac for two wire 240 volt models after a delay
of approximately 5 seconds.
15. Move the probe's flat end to the dispenser hous-
ing. The indication must be 0.
LEVEL CONTROL BOARD AND LEVEL PROBE
(cont.)
16. Move the probe's flat end away from the dispenser
housing. The indication should again be 120 volts
ac for two wire 120 volt models, three wire 120/
208 volt models, three wire 120/240 volt models
and 240 volt ac for two wire 240 volt models after
a delay of approximately 5 seconds.
If voltage is present as described, reinstall the probe,
the level control board and level probe are operating
properly.
If voltage is not present as described, check the pink
probe wire for continuity.
Removal and Replacement:
1. Remove all wires from the level control board.
2. Remove two #8-32 keps nuts holding level control
board to right side of the component bracket.
3. Remove level control board and spacers.
3. Install the new level control board and spacers to
the right side of the component bracket using two
#8-32 keps nuts.
4. Refer to Fig. 19 when reconnecting the wires.
P1455
FIG. 19 LEVEL BOARD TERMINALS
T1 VIO to Inlet
Solenoid Coil
T2 BLU to Overflow
Protection Switch
T3 WHI to Main
Harness
T4 PNK to Probe
GRN to Tank
28364 011598
Vue de la page 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 35 36

Commentaires sur ces manuels

Pas de commentaire