Bunn ULTRA-2 Manuel de service Page 3

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 34
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 2
3
USER NOTICES
Carefully read and follow all notices on the equipment and in this manual. They were written for your protec-
tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels.
27442.0000
! WARNING
DO NOT OVERLOAD CIRCUIT.
ALWAYS ELECTRICALLY GROUND THE CHASSIS
OR ADAPTOR PLUG.
DO NOT DEFORM PLUG OR CORD.
FOLLOW NATIONAL AND LOCAL ELECTRICAL CODES.
KEEP COMBUSTIBLES AWAY.
FAILURE TO COMPLY RISKS EQUIPMENT
DAMAGE, FIRE OR SHOCK HAZARD.
READ THE ENTIRE OPERATING MANUAL
BEFORE USING THIS PRODUCT
00986.0002E 5/98 ©1994 Bunn-O-Matic Corporation
32162.0000 (ULTRA-2)
00986.0002
CHARGE
Type R404A, Amount 9.5 oz(269g)
Design Pressures: High 215 Low 40
29373.0000 (ULTRA-2A)
SITE PREPARATION
The dispenser is very heavy. Place it on a sturdy counter or shelf capable of supporting at least 180 lbs. It is
for indoor use only.
The dispenser must have at least six inches of space behind it. This space is needed for airflow, air filter removal,
and cleaning. A clearance of at approximately six inches is recommended between the dispenser sides and the wall
or another appliance. The dispenser performs better if not placed near any heating appliance. Leave some space
so the dispenser can be moved for cleaning.
ELECTRICAL REQUIREMENTS
CAUTION – Improper electrical installation will damage components. An electrician must provide electrical service
as specified below.
Model ULTRA-2, This dispenser has an attached cordset and requires a 2-wire, grounded, individual branch circuit
rated 120 volts ac, 15 amp, single phase, 60 Hz. The mating connector must be a NEMA 5-15R.
(Refer to the dataplate for exact electrical requirements.)
Model ULTRA-2A, This dispenser has an attached cordset and requires a 2-wire, grounded, individual branch
circuit rated 230 volts ac, 10 amp, single phase, 50 Hz.
(Refer to the dataplate for exact electrical requirements.)
NOTE – Bunn-O-Matic does not recommend the use of any extension cord with these dispensers.
CHARGE
Type R404A, Amount 10 oz
Design Pressures: High 240 Low 34
Risk of Electric Shock.
This equipment may have two power
supply cords. Unplug all cords before
moving or servicing this equipment.
29947.0000
INTENDED FOR USE AT A
ROOM TEMPERATURE OF
27°C (80°F)
29979.0000
32080.0001 021105