Location:
The Control Board is located inside the back cover.
Test Procedures:
The test procedures for the control board will vary
depending upon the problem. Refer to the Troubleshooting
section which is divided into three sections, Refill Circuit,
Heating Circuit, and Brewing Circuit.
CheckforPowertoboard:
1. Place one meter lead at L1 terminal and the other lead
at L2 terminal.
2. With the power connected to brewer, the voltage read-
ing to the board should be the line voltage rated for that
model.
Ifnovoltageispresent,checkwiringtotheboard.
Ifvoltageispresent,andbrewerdoesnotpower
on,replaceboard.
RemovalandReplacement:
1. Disconnect brewer from power source.
2. Disconnect the cord from L1 & L2 on the control board.
3. Disconnect the connectors from the control board.
4. Remove the 6 screws securing the control board to
the mounting bracket.
5. Install new board with screws removed in # 4.
6. Re-install wires & connectors.
FIG.11-1CONTROLBOARD-AutoPod
CONTROL BOARD
FIG.11-2CONTROLBOARD-MyCaféAP
41169 120711
SW1
PRGM
LOCK
SET
ON
J3 J1
J11
J4
J7
J12
J8
J2
J6
4 3
2 1
J5
1
2
3
4
5
1
2
3
1 2 3 4 6 5 4 3 2 1 2 1
2 1
1
2
1
3
2
4
RED (TH4/MOV1)
BRN (TH2/MOV2)
YEL (TH3/MOV3)
TR 1 – Heater Output (Line Voltage)
RED – Solenoid (Line Voltage)
BRN – Solenoid (Line Voltage)
YEL – Rectified Line Voltage