Location:
The vent valve is located inside the back access panel.
Function:
The vent valve closes (activates) only during hot water
dispense to pressurize tank.
Test Procedures:
1. With a voltmeter, check voltage across the termi-
nals of the vent valve. Activate valve in the "TEST
OUTPUTS" program mode. The indication must
be 12 vdc.
2. Coil resistance should be 28.8 ±10%.
RemovalandReplacement:
1. Disconnect the brewer from the power source.
2. Disconnect the connectors from solenoid.
3. Cut cable tie(s) securing solenoid.
4. Disconnect hose from solenoid.
5. Install in reverse order.
FIG.15-1VENTVALVE-MyCaféAP
FIG.15-2VENTVALVE-AutoPod
VENT VALVE